Diagnosis Procedure
- CHECK FUEL PUMP CONTROL MODULE POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect Fuel pump control module harness connector.
- Turn ignition switch ON.
- Check the voltage between Fuel pump control module harness connector and ground.
+
-
Voltage
Fuel pump control module
Connector
Terminal
B50
6
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 2.
- CHECK FUEL PUMP CONTROL MODULE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and Fuel pump control module harness connector.
IPDM E/R
Fuel pump control module
Continuity
Connector
Terminal
Connector
Terminal
E121
15
B50
6
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace error-detected parts.
- CHECK FUSE
Check that the following fuse is not blowing.
Location
Fuse No.
Capacity
IPDM E/R
#47
15A
Is the fuse blown (open)?
YES
Replace the fuse after repairing the applicable circuit.
NO
GO TO 4.
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to Intermittent Incident .
Is the inspection result normal?
YES
Perform trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK FUEL PUMP CONTROL MODULE GROUND CIRCUIT
- Turn ignition switch OFF.
- Check the continuity between Fuel pump control module harness connector and ground.
Fuel pump control module
--
Continuity
Connector
Terminal
B50
3
Ground
Existed
- Also check harness for short to power.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair or replace error-detected parts.
- CHECK FUEL PUMP CONTROL MODULE INPUT AND OUTPUT CIRCUITS
- Disconnect ECM harness connector.
- Check the continuity between Fuel pump control module harness connector and ECM harness connector.
Fuel pump control module
ECM
Continuity
Connector
Terminal
Connector
Terminal
B50
4
E32
182
Existed
5
188
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO 7.
NO
Repair or replace error-detected parts.
- CHECK FUEL PUMP CONTROL CIRCUIT
- Disconnect "fuel level sensor unit and fuel pump" harness connector.
- Check the continuity between Fuel pump control module harness connector and "fuel level sensor unit and fuel pump" harness connector.
Fuel pump control module
Fuel level sensor unit and fuel pump
Continuity
Connector
Terminal
Connector
Terminal
B50
1
B72
6
Existed
2
4
Is the inspection result normal?
YES
GO TO 8.
NO
Repair or replace error-detected parts.
- CHECK FUEL PUMP
Check fuel pump. Refer to Component Inspection (Fuel Pump) .
Is the inspection result normal?
YES
GO TO 9.
NO
Replace fuel level sensor, fuel filter and fuel pump assembly. Refer to Removal and Installation .
- CHECK FUEL PUMP CONTROL MODULE
Check fuel pump control module. Refer to Component Inspection (Fuel Pump Control Module) .
Is the inspection result normal?
YES
Check intermittent incident. Refer to Intermittent Incident .
NO
Replace fuel pump control module. Refer to Removal and Installation .