Diagnosis Procedure
- CHECK VACUUM SOURCE
- Turn ignition switch OFF.
- Reconnect electronic controlled engine mount control solenoid valve harness connector.
- Disconnect vacuum hose connected to electronic controlled engine mount.
- Start engine and let it idle.
- Check vacuum hose for vacuum existence.
Vacuum should exist.
Is the inspection result normal?
YES
GO TO 7.
NO
GO TO 2.
- CHECK VACUUM HOSES AND VACUUM GALLERY
- Turn ignition switch OFF.
- Check vacuum hoses and vacuum gallery for clogging, cracks or improper connection. Refer to System Description .
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace vacuum hoses and vacuum gallery.
- CHECK ELECTRONIC CONTROLLED ENGINE MOUNT CONTROL SOLENOID VALVE POWER SUPPLY
- Disconnect electronic controlled engine mount control solenoid valve harness connector.
- Turn ignition switch ON.
- Check the voltage between front electronic controlled engine mount harness connector and ground.
+
-
Voltage
Electronic controlled engine mount control solenoid valve
Connector
Terminal
F64
1
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 4.
- CHECK ELECTRONIC CONTROLLED ENGINE MOUNT CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect fuse block (J/B) harness connector.
- Check the continuity between electronic controlled engine mount harness connector and fuse block (J/B) harness connector.
Electronic controlled engine mount control solenoid valve
Fuse block (J/B)
Continuity
Connector
Terminal
Connector
Terminal
F64
1
E28
1M
Existed
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK ELECTRONIC CONTROLLED ENGINE MOUNT CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Disconnect ECM harness connector.
- Check the continuity between ECM harness connector and electronic controlled engine mount control solenoid valve harness connector.
ECM
Electronic controlled engine mount control solenoid valve
Continuity
Connector
Terminal
Connector
Terminal
F79
137
F64
2
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair open circuit, short to ground or short to power in harness connectors.
- CHECK ELECTRONIC CONTROLLED ENGINE MOUNT CONTROL SOLENOID VALVE
Check electronic controlled engine mount control solenoid valve. Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 7.
NO
Replace electronic controlled engine mount control solenoid valve. Refer to VALVE TIMING CONTROL .
- CHECK ELECTRONIC CONTROLLED ENGINE MOUNT
- Turn ignition switch OFF.
- Install vacuum pump (A) to electronic controlled engine mount
.
- Check that a vacuum is maintained when applying the vacuum of -40 kPa (-0.41 kg/cm 2 , -5.8 psi) to electronic controlled engine mount.
- Also visually check electronic controlled engine mount.
Is the inspection result normal?
YES
GO TO 8.
NO
Replace electronic controlled engine mount.
- CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to Intermittent Incident .
Is the inspection result normal?
YES
Replace intake manifold collector. Refer to INTAKE MANIFOLD COLLECTOR .
NO
Repair or replace error-detected parts.