Circuit Diagnosis Procedure
- CHECK INTERIOR ROOM LAMP CONTROL OUTPUT
CONSULT
- Place each interior room lamp switch into the DOOR position on an individual basis. Test each of the following switches individually.
- Front room/map lamp
- Cargo lamp
- Personal lamp 2nd row (if equipped)
- Personal lamp 3rd row (if equipped)
- Personal lamp 4th row (if equipped)
- Turn ignition switch ON.
- Select "INT LAMP" of BCM (INT LAMP) active test item.
- While operating the test item, check voltage between BCM connector M20 terminal 63 and ground.
(+)
(-)
INT LAMP
Voltage
Connector
Terminal
M20
63
Ground
ON
0V
OFF
Battery voltage
Is the inspection result normal?
YES
Interior room lamp control circuit is operating normally.
Fixed ON
GO TO 3
Fixed OFF
GO TO 2
- Place each interior room lamp switch into the DOOR position on an individual basis. Test each of the following switches individually.
- CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector M20 and interior room lamp harness connector in question.
- Check continuity between BCM connector M20 terminal 63 and interior room lamp harness connector in question.
BCM
Interior room lamp
Continuity
Connector
Terminal
Component
Connector
Terminal
M20
63
Front room/map lamp
R25
3
Yes
Personal lamp 2nd row
B402
3
Personal lamp 3rd row
B403
3
Personal lamp 4th row
B404
3
Cargo lamp
B23
2
Is the inspection result normal?
YES
Check interior room lamps for an open. If NG, replace lamp in question. Refer to Removal and Installation (Front Room/Map Lamp), Removal and Installation - Front, Center or Rear (Cargo Lamp) or Removal and Installation (Personal Lamp). If OK, replace BCM. Refer to Removal and Installation .
NO
Repair the harness or connectors.
- CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM harness connector M20.
- Check continuity between BCM harness connector M20 terminal 63 and ground.
Connector
Terminal
-
Continuity
M20
63
Ground
No
Is the inspection result normal?
YES
Check interior room lamps for a short circuit. If NG, replace lamp in question. Refer to Removal and Installation (Front Room/Map Lamp), Removal and Installation - Front, Center or Rear (Cargo Lamp) or Removal and Installation (Personal Lamp). If OK, replace BCM. Refer to Removal and Installation .
NO
Repair the harness or connectors.