Diagnosis Procedure
- CHECK DTC PRIORITY
- Turn ignition switch ON.
- Connect CONSULT and check for "ENGINE" diagnostic trouble codes.
- Are any of the following displayed as current on the CONSULT screen:
- P0562-00
- P0563-00
- P0687-00
Is applicable DTC detected?
YES
Refer to DTC Index .
NO
GO TO 2 .
- CHECK DTC PRIORITY
- Turn ignition switch ON.
- Connect CONSULT and check for "ENGINE" diagnostic trouble codes.
- Are any of the following displayed as current on the CONSULT screen:
- U0106-00
- U010C-00
- U010E-00
- U029D-00
- U029E-00
- U1611-00
- U1612-00
Is applicable DTC detected?
YES
Replace IPDM E/R. Refer to Removal and Installation of IPDM E/R .
NO
GO TO 3 .
- CHECK BATTERY TERMINALS
- Turn ignition switch OFF.
- Check the battery terminal connections.
Are the battery terminal connections tight and corrosion free?
YES
GO TO 4 .
NO
Tighten and clean the terminals.
- CHECK BATTERY VOLTAGE
- Turn ignition switch ON.
- Measure the voltage from the positive battery terminal to the negative battery terminal.
Is the battery voltage at least 12V?
YES
GO TO 5 .
NO
Charge or replace battery(s). Refer to Removal and Installation - CUMMINS 5.0L .
- INSPECT ROTARY TURBINE CONTROL VALVE ACTUATOR AND CONNECTOR PINS
- Turn ignition switch OFF.
- Disconnect rotary turbine control valve actuator harness connector F146.
- Inspect the harness connector and rotary turbine control valve actuator pins for the following:
- Loose connector
- Corroded pins
- Bent or broken pins
- Pushed back or expanded pins
- Moisture in or on the connector
- Missing or damaged connector seals
- Dirt or debris on or in the connector pins
- Connector shell broken
- Wire insulation damage
- Damaged connector locking tab
Is the inspection result normal?
YES
GO TO 6 .
NO
Repair or replace error-detected parts.
- CHECK THE ROTARY TURBINE CONTROL VALVE ACTUATOR SUPPLY VOLTAGE AND RETURN CIRCUIT
- Turn ignition switch OFF.
- Disconnect the rotary turbine control valve actuator harness connector F146.
- Turn ignition switch ON.
- Measure the voltage between rotary turbine control valve actuator harness connector F146 terminals 1 and 4.
Rotary turbine control valve actuator
Voltage
(Approx.)
Connector
Terminal
Terminal
F146
1
4
> 10V
Is inspection result normal?
YES
Replace rotary turbine control valve actuator. Refer to Removal and Installation .
NO
GO TO 7.
- CHECK THE ROTARY TURBINE CONTROL VALVE ACTUATOR VOLTAGE
- Turn ignition switch OFF.
- Disconnect the rotary turbine control valve actuator harness connector F146.
- Turn ignition switch ON.
- Measure the voltage between rotary turbine control valve actuator harness connector F146 terminal 4 and ground.
Rotary turbine control valve actuator
Ground
Voltage
(Approx.)
Connector
Terminal
F146
4
-
> 10V
Is inspection result normal?
YES
Repair or replace harness for an open ground circuit.
NO
Repair or replace harness for an open battery voltage supply circuit.