DTC Detection Logic
The ECM detected a read or write error internal to the ECM.
|
DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition |
||
|
P0607-00 |
Control Module Performance (Engine control module warning internal hardware failure - bad intelligent device or component) |
1 |
Diagnosis condition |
Ignition is ON or engine is running |
|
Signal (terminal) |
- |
|||
|
Threshold |
The ECM stays powered on after the ignition is turned off |
|||
|
Diagnosis delay time |
Diagnostic runs continuously when the engine is running |
|||
|
2 |
Diagnosis condition |
Ignition is ON or engine is running |
||
|
Signal (terminal) |
- |
|||
|
Threshold |
The monitoring microprocessor commands the torque actuator circuits (typically injector drivers) to shut down, but the torque actuator circuit feedbacks indicate the circuit is still active |
|||
|
Diagnosis delay time |
Diagnostic runs continuously when the engine is running |
|||
|
3 |
Diagnosis condition |
Ignition is ON or engine is running |
||
|
Signal (terminal) |
- |
|||
|
Threshold |
The check sum of the ECM sub-processor memory does not equal the expected checksum or the independent internal watchdog timer updated in conjunction with the sub-processors intended instructions indicates operation processing is lost > 500 microseconds or the register value of the sub-processor is not equal to the expected value in normal operation |
|||
|
Diagnosis delay time |