Diagnosis Procedure
- CHECK CONNECTOR
Check the damage and corrosion of connectors (F214 and F216 and E73 and E74).
Is the inspection result normal?
YES
GO TO 2 .
NO
Repair or replace malfunctioning parts.
- CHECK A/T FLUID TEMPERATURE SENSOR 2 CIRCUIT
- Turn ignition switch OFF.
- Disconnect TCM connector.
- Check continuity between TCM harness connector terminals and ground.
TCM
-
Continuity
Connector
Terminal
E73
65
Ground
Not existed
66
Is the inspection result normal?
YES
GO TO 3 .
NO
Repair or replace malfunctioning parts.
- CHECK CIRCUIT BETWEEN A/T FLUID TEMPERATURE SENSOR 2 AND ANOTHER CIRCUIT
Check continuity between TCM harness connector terminals.
TCM
Continuity
Connector
Terminal
E73
65
Other than the 65
Not existed
66
Other than the 66
Is the inspection result normal?
YES
GO TO 4 .
NO
Repair or replace malfunctioning parts.
- CHECK A/T FLUID TEMPERATURE SENSOR 2 CIRCUIT
- Turn ignition switch ON.
- Check voltage between TCM harness connector terminals and ground.
TCM
-
Voltage
Connector
Terminal
E73
65
Ground
Other than the battery voltage
66
Is the inspection result normal?
YES
GO TO 5 .
NO
Repair or replace malfunctioning parts.
- CHECK A/T FLUID TEMPERATURE SENSOR 2 CIRCUIT
- Turn ignition switch OFF.
- Disconnect TCM connector.
- Check continuity between TCM harness connector terminals and A/T assembly connector terminals.
Is there continuity exist?
YES
Replace the A/T fluid temperature sensor 2. Refer to Removal and Installation .
NO
Repair or replace malfunctioning parts.