Diagnosis Procedure
- CHECK TRANSFER CONTROL UNIT POWER SUPPLY (1)
- Turn the ignition switch OFF.
- Disconnect transfer control unit harness connector.
- Check the voltage between transfer control unit harness connector and ground.
Transfer control unit
-
Voltage
(Approx.)
Connector
Terminal
E142
1
Ground
Battery voltage
- Turn the ignition switch ON.CAUTION: Never start the engine.
- Check the voltage between transfer control unit harness connector and ground.
Transfer control unit
-
Voltage
(Approx.)
Connector
Terminal
E142
1
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 3 .
NO
GO TO 2 .
- CHECK TRANSFER CONTROL UNIT POWER SUPPLY (2)
- Turn the ignition switch OFF.
- Check the 10A fuse (#59).
- Check the harness for open or short between transfer control unit harness connector No. 1 terminal and fuse box.
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit. Refer to the appropriate Wiring Diagram
NO
Repair or replace error-detected parts.
- CHECK TRANSFER CONTROL UNIT POWER SUPPLY (3)
- Turn the ignition switch OFF.
- Check the voltage between transfer control unit harness connector and ground.
Transfer control unit
-
Voltage
(Approx.)
Connector
Terminal
E142
4
Ground
0 V
- Turn the ignition switch ON.CAUTION: Never start the engine.
- Check the voltage between transfer control unit harness connector and ground.
Transfer control unit
-
Voltage
(Approx.)
Connector
Terminal
E142
4
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 5 .
NO
GO TO 4 .
- CHECK TRANSFER CONTROL UNIT POWER SUPPLY (4)
- Turn the ignition switch OFF.
- Check the 10A fuse (#30).
- Disconnect fuse block (J/B) harness connector.
- Check the continuity between transfer control unit harness connector and fuse block (J/B) harness connector.
Fuse block (J/B)
Transfer control unit
Continuity
Connector
Terminal
Connector
Terminal
M69
1M
E142
4
Yes
- Check the continuity between transfer control unit harness connector and the ground.
Transfer control unit
-
Continuity
Connector
Terminal
E142
4
Ground
No
Is the inspection result normal?
YES
Perform the trouble diagnosis for ignition power supply circuit. Refer to the appropriate Wiring Diagram
NO
Repair or replace error-detected parts.
- CHECK TRANSFER CONTROL UNIT GROUND
- Turn the ignition switch OFF.
- Check the voltage between transfer control unit harness connector and ground.
Transfer control unit
-
Voltage
(Approx.)
Connector
Terminal
E142
2
Ground
0 V
3
- Check the continuity between transfer control unit harness connector and ground.
Transfer control unit
-
Continuity
Connector
Terminal
E142
2
Ground
Yes
3
Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace error-detected parts.