Diagnosis Procedure
The output voltage of the generator is controlled by the IC regulator at terminal "S" detecting the input voltage. Terminal "S" circuit detects the battery voltage to adjust the generator output voltage with the IC regulator.
- CHECK TERMINAL "S" CONNECTION
1.Turn ignition switch OFF
2.Check if terminal "S" is clean and tight.
Is the inspection result normal?
YES
GO TO 2 .
NO
Repair terminal "S" connection. Confirm repair by performing system test using DSS-5000P NI. Refer to the applicable Instruction Manual for proper testing procedures.
- CHECK VOLTAGE REGULATOR CIRCUIT
Check voltage between generator harness connector and ground.
(+)
(-)
Voltage
(Approx.)
Connector
Terminal
F205 (with Cummins 5.0L)
F242 (with VK56VD)
3
Ground
Battery voltage
Does battery voltage exist?
YES
Refer to Work Flow (With DSS-5000P NI) (with Cummins 5.0L) , Work Flow (With DSS-5000P NI) (with VK56VD) , Work Flow (Without DSS-5000P NI) (with Cummins 5.0L) or Work Flow (Without DSS-5000P NI) (with VK56VD) .
NO
Check harness for open between generator and fuse.