Diagnosis Procedure
The terminal "L" circuit controls the charge warning lamp. The charge warning lamp turns ON when the ignition switch is set to ON or START. When the generator is providing sufficient voltage with the engine running, the charge warning lamp turns OFF. If the charge warning lamp illuminates with the engine running, a malfunction is indicated.
- CHECK TERMINAL "L" CONNECTION
- Turn ignition switch OFF.
- Check if terminal L is clean and tight.
Is the inspection result normal?
YES
GO TO 2.
NO
Repair terminal "L" connection. Confirm repair by performing system test using DSS-5000P NI. Refer to applicable Instruction Manual for proper testing procedures.
- CHECK TERMINAL "L" CIRCUIT (OPEN)
- Disconnect the generator connector.
- Apply ground to generator harness connector.
- Check condition of the charge warning lamp with the ignition switch in the ON position.
Generator
Ground
Condition
Connector
Terminal
Ignition switch position
Charge warning lamp
F205 (with Cummins 5.0L)
F242 (with VK56VD)
2
ON
Illuminate
Does it illuminate?
YES
Terminal "L" circuit is normal. Refer to Work Flow (With DSS-5000P NI) (with Cummins 5.0L) , Work Flow (With DSS-5000P NI) (with VK56VD) , Work Flow (Without DSS-5000P NI) (with Cummins 5.0L) , or Work Flow (Without DSS-5000P NI) (with VK56VD) .
NO
GO TO 3.
- CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
- Disconnect the battery cable from the negative terminal.
- Disconnect the combination meter connector.
- Check continuity between generator harness connector and combination meter harness connector.With Cummins 5.0L
Generator
Combination meter
Continuity
Connector
Terminal
Connector
Terminal
F205
2
M25
11
Yes
With VK56VD (with type A combination meter)Generator
Combination meter
Continuity
Connector
Terminal
Connector
Terminal
F242
2
M25
11
Yes
With VK56VD (with type B combination meter)Generator
Combination meter
Continuity
Connector
Terminal
Connector
Terminal
F242
2
M163
11
Yes
Is the inspection result normal?
YES
GO TO 4.
NO
Repair or replace the harness or connectors.
- CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
Check continuity between combination meter harness connector and fuse block (J/B).
With Cummins 5.0LCombination meter
Fuse box (J/B)
Continuity
Connector
Terminal
Connector
Terminal
M24
42
M4
13P
Yes
With VK56VD (with type A combination meter)Combination meter
Fuse box (J/B)
Continuity
Connector
Terminal
Connector
Terminal
M24
42
M4
13P
Yes
With VK56VD (with type B combination meter)Combination meter
Fuse box (J/B)
Continuity
Connector
Terminal
Connector
Terminal
M163
6
M4
13P
Yes
Is the inspection result normal?
YES
GO TO 5.
NO
Repair or replace the harness or connectors.
- CHECK POWER SUPPLY CIRCUIT
- Connect the battery cable to the negative terminal.
- Check voltage between combination meter harness connector and ground.With Cummins 5.0L
(+)
(-)
Condition
Voltage
(Approx.)
Combination meter
Connector
Terminal
M24
42
Ground
When the ignition switch is in ON position
Battery voltage
With VK56VD (with type A combination meter)(+)
(-)
Condition
Voltage
(Approx.)
Combination meter
Connector
Terminal
M24
42
Ground
When the ignition switch is in ON position
Battery voltage
With VK56VD (with type B combination meter)(+)
(-)
Condition
Voltage
(Approx.)
Combination meter
Connector
Terminal
M163
6
Ground
When the ignition switch is in ON position
Battery voltage
Is the inspection result normal?
YES
Replace the combination meter. Refer to Removal and Installation .
NO
Repair or replace the harness or connectors.