LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 187 (Interior Lighting System (Circuit Diagnosis)) >> Circuit Diagnosis >> Interior Room Lamp Control Circuit >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2018 Nissan Titan XD and 2018 Nissan Titan. However, it is still accessible from the selected car via links, so may be relevant.

Controls the following interior room lamps (ground side) by pulse width modulated signal

  1. CHECK INTERIOR ROOM LAMP CONTROL OUTPUT 

    SYMBOL CONSULT

    1. Switch the front room/map lamp assembly and personal lamp switch to DOOR.
    2. Turn ignition switch ON.
    3. Select "INT LAMP" in "Active Test" mode of "BCM".
    4. While operating the test item, check voltage between BCM connector M81 terminal 136 and ground.

    BCM

    (-)

    Test item

    Voltage

    (Approx.)

    (+)

    Connector

    Terminal

    M81

    136

    Ground

    INT LAMP

    On

    0V

    Off

    Battery voltage

    Is the inspection result normal?

    YES

    Interior room lamp control circuit is operating normally.

    Fixed ON

    GO TO 3 .

    Fixed OFF

    GO TO 2.

  2. CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect BCM connector M81, door mirror connectors D4 and D107 (with puddle lamps) (if equipped), front room/map lamp assembly connector R13 (with front roof console) or front room/map lamp assembly connector R14 (without front roof console) and personal lamp connector R11.
    3. Check continuity between BCM connector M81 terminal 136 and door mirror connectors D4 and D107 terminal 22 (with puddle lamps) (if equipped), front room/map lamp assembly connector R13 terminal 4 (with front roof console) or front room/map lamp assembly connector R14 terminal 3 (without front roof console) and personal lamp connector R11 terminal 3.

      BCM

      Each interior room lamp

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      M81

      136

      Door mirror LH (puddle lamps)

      (if equipped)

      D4

      22

      Yes

      Door mirror RH (puddle lamps)

      (if equipped)

      D107

      22

      Front room/map lamp assembly (with front roof console)

      R13

      4

      Front room/map lamp assembly (without front roof console)

      R14

      3

      Personal lamp

      R11

      3

    Is the inspection result normal?

    YES

    Check interior room lamps for an open circuit. If OK, replace BCM. Refer to Removal and Installation . If open circuit is found, replace interior room lamp. Refer to Removal and Installation .

    NO

    Repair the harness or connectors.

  3. CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect BCM connector M81, door mirror connectors D4 and D107 (with puddle lamps) (if equipped), front room/map lamp assembly connector R13 (with front roof console) or front room/map lamp assembly connector R14 (without front roof console) and personal lamp connector R11.
    3. Check continuity between BCM connector M81 terminal 136 and ground.

      BCM

      (-)

      Continuity

      Connector

      Terminal

      M81

      136

      Ground

      No

    Is the inspection result normal?

    YES

    Check interior room lamps for a short circuit. If OK, replace BCM. Refer to Removal and Installation . If short is found, replace interior room lamp. Refer to Removal and Installation .

    NO

    Repair the harness or connectors.