Diagnosis Procedure
Provides the battery saver output/power supply. Cuts the power supply when the interior room lamp battery saver is activating.
- CHECK BATTERY SAVER OUTPUT/POWER SUPPLY OUTPUT
CONSULT
- Turn ignition switch ON.
- Select "Battery Saver" in "Active Test" mode of "BCM".
- While operating the test item, check voltage between BCM connector M81 terminal 129 and ground.
BCM
(-)
Test item
Voltage
(Approx.)
(+)
Connector
Terminal
M81
129
Ground
BATTERY SAVER
Off
Battery voltage
On
0V
Is the inspection result normal?
YES
GO TO 2 .
NO
Replace BCM after making sure the battery saver output/power supply circuit is not shorted to voltage. Refer to Removal and Installation .
- CHECK BATTERY SAVER OUTPUT/POWER SUPPLY OPEN CIRCUIT
- Turn ignition switch OFF.
- Disconnect the following connectors.
- BCM M81
- Door mirror LH (with puddle lamps) (if equipped) D4
- Door mirror RH (with puddle lamps) (if equipped) D107
- Front room/map lamp assembly (with front roof console) (if equipped) R13
- Front room/map lamp assembly (without front roof console) (if equipped) R14
- Vanity lamp LH (if equipped) R3
- Vanity lamp RH (if equipped) R8
- Front foot lamp LH (if equipped) M93
- Front foot lamp RH (if equipped) M92
- Personal lamp R11
- Check continuity between BCM connector M81 terminal 129 and each interior room lamp connector.
BCM
Each interior room lamp
Continuity
Connector
Terminal
Connector
Terminal
M81
129
Door mirror LH (with puddle lamps) (if equipped)
D4
21
Yes
Door mirror RH (with puddle lamps) (if equipped)
D107
21
Front room/map lamp assembly (with front roof console) (if equipped)
R13
1
Front room/map lamp assembly (without front roof console) (if equipped)
R14
1
Vanity lamp LH (if equipped)
R3
1
Vanity lamp RH (if equipped)
R8
1
Front foot lamp LH (if equipped)
M93
1
Front foot lamp RH (if equipped)
M92
1
Personal lamp
R11
1
Is the inspection result normal?
YES
GO TO 3 .
NO
Repair the harness or connectors.
- CHECK BATTERY SAVER OUTPUT/POWER SUPPLY SHORT CIRCUIT
Check continuity between BCM connector M81 terminal 129 and ground.
BCM
(-)
Continuity
Connector
Terminal
M81
129
Ground
No
Is the inspection result normal?
YES
Check that each interior room lamp has no internal short circuit.
NO
Repair the harness or connectors.