LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 184 (Heater & Air Conditioning Control System - Manual Air Conditioner) >> Ecu Diagnosis Information >> Front Air Control >> Reference Value >> Physical Values

Physical Values

WARNING: This page is about a different car, the 2018 Nissan Titan XD and 2018 Nissan Titan. However, it is still accessible from the selected car via links, so may be relevant.

Terminal No.

(Wire color)

Description

Condition

Value

(Approx.)

+

-

Signal name

Input/Output

1

(L)

-

CAN high

Input/Output

-

-

2

(B)

-

Ground

-

-

-

3

(SB)

Ground

Battery power supply

Input

Ignition switch OFF

Battery voltage

4

(L)

Ground

Illumination (+)

ON

Lighting switch

OFF

0 V

1st position

Battery voltage

9

(W)

Ground

IGN 2

Input

Ignition switch ON

Battery voltage

10

(P)

Ground

Front blower motor control signal

Output

  • Ignition switch ON
  • Front fan speed: 1st speed (manual)
GNSJSIIA0096Z-096Courtesy of NISSAN NORTH AMERICA, INC.

11

(Y)

Ground

RR DEF switch

Output

Defroster switch

OFF

0 V

ON

5 V

12

(G)

Ground

Each door motor LIN signal

Input/Output

Ignition switch ON

G04077879Courtesy of NISSAN NORTH AMERICA, INC.

13

(W)

Ground

Each door motor power supply

Output

Ignition switch ON

Battery voltage

17

(P)

-

CAN low

Input/Output

-

-

18

(B)

-

Ground

-

-

-

19

(G)

Ground

Ignition power supply

Input

Ignition switch ON

Battery voltage

20

(GR)

-

Illumination (-)

-

-

0 V

21

(R)

-

Sensor ground

-

-

-

22

(P)

Ground

Intake sensor signal

Input

Ignition switch ON

0 - 4.8 V

Output voltage varies with front evaporator fin temperature

25

(Y)

Ground

Compressor ON signal

ON

A/C switch OFF

5 V

ON

A/C switch ON

0 V

26

(L/W)

Ground

Front blower motor feedback

ON

-

Battery voltage

27

(B/W)

Ground

RR DEF feedback

Input

Defroster switch

OFF

0 V

ON

Battery voltage

29

(B)

-

ACTR Ground

-

-

-

30

(W)

Ground

Fan ON signal

ON

Blower switch OFF

5 V

ON

Blower switch ON

0 V