Physical Values
|
Terminal No. (Wire color) |
Description |
Condition |
Value (Approx.) |
|||
|
+ |
- |
Signal name |
Input/Output |
|||
|
1 (L) |
- |
CAN high |
Input/Output |
- |
- |
|
|
2 (B) |
- |
Ground |
- |
- |
- |
|
|
3 (SB) |
Ground |
Battery power supply |
Input |
Ignition switch OFF |
Battery voltage |
|
|
4 (L) |
Ground |
Illumination (+) |
ON |
Lighting switch |
OFF |
0 V |
|
1st position |
Battery voltage |
|||||
|
9 (W) |
Ground |
IGN 2 |
Input |
Ignition switch ON |
Battery voltage |
|
|
10 (P) |
Ground |
Front blower motor control signal |
Output |
|
||
|
11 (Y) |
Ground |
RR DEF switch |
Output |
Defroster switch |
OFF |
0 V |
|
ON |
5 V |
|||||
|
12 (G) |
Ground |
Each door motor LIN signal |
Input/Output |
Ignition switch ON |
||
|
13 (W) |
Ground |
Each door motor power supply |
Output |
Ignition switch ON |
Battery voltage |
|
|
17 (P) |
- |
CAN low |
Input/Output |
- |
- |
|
|
18 (B) |
- |
Ground |
- |
- |
- |
|
|
19 (G) |
Ground |
Ignition power supply |
Input |
Ignition switch ON |
Battery voltage |
|
|
20 (GR) |
- |
Illumination (-) |
- |
- |
0 V |
|
|
21 (R) |
- |
Sensor ground |
- |
- |
- |
|
|
22 (P) |
Ground |
Intake sensor signal |
Input |
Ignition switch ON |
0 - 4.8 V Output voltage varies with front evaporator fin temperature |
|
|
25 (Y) |
Ground |
Compressor ON signal |
ON |
A/C switch OFF |
5 V |
|
|
ON |
A/C switch ON |
0 V |
||||
|
26 (L/W) |
Ground |
Front blower motor feedback |
ON |
- |
Battery voltage |
|
|
27 (B/W) |
Ground |
RR DEF feedback |
Input |
Defroster switch |
OFF |
0 V |
|
ON |
Battery voltage |
|||||
|
29 (B) |
- |
ACTR Ground |
- |
- |
- |
|
|
30 (W) |
Ground |
Fan ON signal |
ON |
Blower switch OFF |
5 V |
|
|
ON |
Blower switch ON |
0 V |
||||