Diagnosis Procedure
- CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
- Turn the ignition switch OFF.
- Disconnect the battery cable from the negative terminal.
- Disconnect the following harness connectors.
- ECM
- Combination meter
- Front air control (with manual air conditioning system)
- A/C auto amp. (with automatic air conditioning system)
- Check the continuity between the combination meter harness connector and the front air control or the A/C auto amp. harness connector.
- With type A (with manual air conditioning system)
Combination meter harness connector
Front air control harness connector
Continuity
Connector No.
Terminal No.
Connector No.
Terminal No.
M25
46
M132
1
Existed
45
17
Existed
- With type A (with automatic air conditioning system)
Combination meter harness connector
A/C auto amp. harness connector
Continuity
Connector No.
Terminal No.
Connector No.
Terminal No.
M25
46
M137
1
Existed
45
21
Existed
- With type B
Combination meter harness connector
Front air control harness connector
Continuity
Connector No.
Terminal No.
Connector No.
Terminal No.
M163
34
M132
1
Existed
35
17
Existed
- With type A (with manual air conditioning system)
NOTE: Check the combination meter type to confirm the service information. Refer to Information .Is the inspection result normal?
YES
Check CAN system type decision again.
YES
Error was detected in the main line between the combination meter and the front air control or the A/C auto amp.
NO
Repair the main line between the combination meter and the front air control or the A/C auto amp.