Values on the Diagnosis Tool
|
Monitor item |
Condition |
Value/Status |
|
|
AMB TEMP SEN |
Ignition switch ON |
- |
-30 - 55°C (22 - 131°F) |
|
IN-VEH TEMP |
Ignition switch ON |
- |
-30 - 55°C (22 - 131°F) |
|
INT TEMP SEN |
Ignition switch ON |
- |
-30 - 55°C (22 - 131°F) |
|
SUNLOAD SEN |
Ignition switch ON |
- |
0 - 1045 w/m 2 (0 - 899 kcal/m 2 .h) |
|
AMB SEN CAL |
Ignition switch ON |
- |
-30 - 55°C (22 - 131°F) |
|
IN-VEH CAL |
Ignition switch ON |
- |
-30 - 55°C (22 - 131°F) |
|
INT TEMP CAL |
Ignition switch ON |
- |
-30 - 55°C (22 - 131°F) |
|
SUNL SEN CAL |
Ignition switch ON |
- |
0 - 1045 w/m 2 (0 - 899 kcal/m 2 .h) |
|
COMP REQ SIG |
Engine: Run at idle after warming up |
A/C switch: ON (A/C compressor operation status) |
On |
|
A/C switch: OFF |
Off |
||
|
FAN REQ SIG |
Engine: Run at idle after warming up |
Blower fan: ON |
On |
|
Blower fan: OFF |
Off |
||
|
FAN DUTY |
Engine: Run at idle after warming up |
Blower fan: ON |
Varies |
|
Blower fan: OFF |
0% |
||
|
XM |
Ignition switch ON |
- |
-100 - 155 |
|
ENG COOL TEMP |
Ignition switch ON |
- |
Varies according to coolant temperature |
|
VEHICLE SPEED |
Driving |
- |
Equivalent to speedometer reading |
|
PA TARGET A/TEMP |
Ignition switch ON |
- |
Value according to target air flow temperature (passenger side) |