Diagnosis Procedure
- CHECK FUSE
- Turn power switch OFF.
- Check that the following fuse in the fuse block (J/B) is not blown.
Signal name
Fuse No.
Battery power supply
13 (10 A)
Is the inspection result normal?
YES
GO TO 2 .
NO
Replace the blown fuse after repairing the cause of blowing.
- CHECK SECURITY INDICATOR LAMP POWER SUPPLY CIRCUIT
- Disconnect combination meter connector.
- Check voltage between combination meter harness connector and ground.Type A meter
(+)
(-)
Condition
Voltage
(Approx.)
Combination meter
Connector
Terminal
M25
42
Ground
Ignition switch
OFF
Battery voltage
ON
Type B meter(+)
(-)
Condition
Voltage
(Approx.)
Combination meter
Connector
Terminal
M163
6
Ground
Ignition switch
OFF
Battery voltage
ON
Is the inspection result normal?
YES
GO TO 3 .
NO
Repair or replace harness.
- CHECK SECURITY INDICATOR LAMP SIGNAL
- Connect combination meter connector.
- Disconnect BCM connector.
- Check voltage between BCM harness connector and ground.
(+)
(-)
Voltage
(Approx.)
BCM
Connector
Terminal
M18
18
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 4 .
NO
GO TO 5 .
- REPLACE BCM
Replace BCM. Refer to Removal and Installation .
Inspection End.
- CHECK SECURITY INDICATOR LAMP CIRCUIT
- Disconnect combination meter connector.
- Check continuity between combination meter harness connector and BCM harness connector.Type A meter
Combination meter
BCM
Continuity
Connector
Terminal
Connector
Terminal
M24
7
M18
18
Yes
Type B meterCombination meter
BCM
Continuity
Connector
Terminal
Connector
Terminal
M163
7
M18
18
Yes
- Check continuity between combination meter harness connector and ground.Type A meter
Combination meter
Ground
Continuity
Connector
Terminal
M24
7
No
Type B meterCombination meter
Ground
Continuity
Connector
Terminal
M163
7
No
Is the inspection result normal?
YES
Replace combination meter. Refer to Removal and Installation (type A meter) and Removal and Installation (type B meter)
NO
Repair or replace harness.