Diagnosis Procedure
- CHECK POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch connectors.
- Turn ignition switch ON.
- Check voltage between main power window and door lock/unlock switch harness connectors and ground.With Crew Cab
(+)
(-)
Voltage
(Approx.)
Main power window and door lock/unlock switch
Connector
Terminal
D7
10
Ground
Battery voltage
D8
18
Except Crew Cab(+)
(-)
Voltage
(Approx.)
Main power window and door lock/unlock switch
Connector
Terminal
D5
8
Ground
Battery voltage
14
Is the inspection result normal?
YES
GO TO 3 .
NO
GO TO 2 .
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector.
- Check continuity between BCM harness connector and main power window and door lock/unlock switch harness connector.With Crew Cab
BCM
Main power window and door lock/unlock switch
Continuity
Connector
Terminal
Connector
Terminal
M81
140
D7
10
Yes
141
D8
18
Except Crew CabBCM
Main power window and door lock/unlock switch
Continuity
Connector
Terminal
Connector
Terminal
M81
140
D5
8
Yes
141
14
- Check continuity between BCM harness connector and ground.
BCM
Ground
Continuity
Connector
Terminal
M81
140
No
141
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between main power window and door lock/unlock switch harness connector and ground.With Crew Cab
Main power window and door lock/unlock switch
Ground
Continuity
Connector
Terminal
D7
1
Yes
Except Crew CabMain power window and door lock/unlock switch
Ground
Continuity
Connector
Terminal
D5
12
Yes
Is the inspection result normal?
YES
GO TO 4 .
NO
Repair or replace harness.
- CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident .
Inspection End.