High-Pressure Fuel System Actuator Override Test: Measurement
WARNING: This page is about a different car, the 2018 Nissan Titan XD. However, it is still accessible from the selected car via links, so may be relevant.
- The HPCR Fuel Act Override Test in CONSULT must be used to run the electric lift pump and open and close the fuel pump actuator and fuel pressure relief valve. Refer to CONSULT Function .
- Select "NO Command" in the drop menu.
- Select Start.NOTE: At this point in the test, the fuel pump actuator and fuel pressure relief valve are in the open position
- Wait for system to run for 30 seconds.
- Observe and record flow from the diagnostic line (steady stream of fuel or no fuel).
- Select Stop.
- Choose HPFS Pressure Relief Valve cdm close in the drop menu.
- Select Start.
- Wait for system to prime (30 seconds)
- Observe and record flow from diagnostic line (steady stream of fuel or no fuel flow).
- Select Stop.
- Choose HPFS Pressure Relief Valve cdm open in the drop menu.
- Repeat steps 7-10.
- Choose HPFS actuator pump cdm close in the drop menu.
- Repeat steps 7-10.
- Choose HPFS actuator pump cdm open in the drop menu.
- Repeat steps 7-10.
- Select End.
- Key off vehicle for at least 70 seconds. This ensures the lift pump stops pumping.CAUTION: The HPCR Fuel Act Override Test cannot be run with the engine running.NOTE: Make sure the diagnostic line is routed in a downward slope toward the breaker. Kinks or uneven hose can skew the test results.
- Expected response of good fuel pump actuator and fuel pressure relief valve:
Trial
Component
State
Expected Response
1
Fuel Pump Actuator
Open
Steady Stream of Fuel
Fuel Pressure Relief Valve
Open
2
Fuel Pump Actuator
Open
No Fuel Flow
Fuel Pressure Relief Valve
Closed
3
Fuel Pump Actuator
Closed
No Fuel Flow
Fuel Pressure Relief Valve
Open
- Expected response of good fuel pump actuator and fuel pressure relief valve: