Diagnosis Procedure
Regarding Wiring Diagram information, refer to the appropriate Wiring Diagram .
- CHECK CAMERA DATA MONITOR
Check CAMERA IMAGE SIG for each camera in "Data Monitor" of "AVM".
Is "OK" displayed for all cameras?
YES
Refer to Intermittent Incident .
NO
GO TO 2
NO
GO TO 4
NO
GO TO 6
NO
GO TO 8
- CHECK FRONT CAMERA POWER SUPPLY AND POWER SUPPLY GROUND CIRCUIT CONTINUITY
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector B83 and front camera connector E169.
- Check continuity between around view monitor control unit connector B83 and front camera connector E169.
Around view monitor control unit
Front camera
Continuity
Connector
Terminal
Connector
Terminal
B83
6
E169
2
Yes
5
1
- Check continuity between around view monitor control unit connector B83 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
B83
6
-
No
Is the inspection result normal?
YES
GO TO 3 .
NO
Repair or replace harness or connectors.
- CHECK AROUND VIEW MONITOR CONTROL UNIT VOLTAGE
- Connect around view monitor control unit connector B83 and front camera connector E169.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit connector B83 terminals.
Around view monitor control unit B83
Condition
Voltage
(Approx.)
(+)
(-)
Terminal
Terminal
6
5
CAMERA switch is ON or shift position is R.
6.2 V
Is the inspection result normal?
YES
Replace front camera. Refer to Removal and Installation .
NO
Replace around view monitor control unit. Refer to Removal and Installation .
- CHECK REAR VIEW CAMERA POWER SUPPLY AND POWER SUPPLY GROUND CIRCUIT CONTINUITY
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector B83 and rear view camera connector C151.
- Check continuity between around view monitor control unit connector B83 and rear view camera connector C151.
Around view monitor control unit
Rear view camera
Continuity
Connector
Terminal
Connector
Terminal
B83
18
C151
1
Yes
17
2
- Check continuity between around view monitor control unit connector B83 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
B83
18
-
No
Is the inspection result normal?
YES
GO TO 5 .
NO
Repair or replace harness or connectors.
- CHECK AROUND VIEW MONITOR CONTROL UNIT VOLTAGE
- Connect around view monitor control unit connector B83 and rear view camera connector C151.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit connector B83 terminals.
Around view monitor control unit B83
Condition
Voltage
(Approx.)
(+)
(-)
Terminal
Terminal
18
17
CAMERA switch is ON or shift position is R.
6.2 V
Is the inspection result normal?
YES
Replace rear view camera. Refer to Removal and Installation .
NO
Replace around view monitor control unit. Refer to Removal and Installation .
- CHECK LH SIDE CAMERA POWER SUPPLY AND POWER SUPPLY GROUND CIRCUIT CONTINUITY
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector B83 and LH side camera connector D4.
- Check continuity between around view monitor control unit connector B83 and LH side camera connector D4.
Around view monitor control unit
LH side camera
Continuity
Connector
Terminal
Connector
Terminal
B83
14
D4
7
Yes
13
19
- Check continuity between around view monitor control unit connector B83 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
B83
14
-
No
Is the inspection result normal?
YES
GO TO 7 .
NO
Repair or replace harness or connectors.
- CHECK AROUND VIEW MONITOR CONTROL UNIT VOLTAGE
- Connect around view monitor control unit connector B83 and LH side camera connector D4.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit connector B83 terminals.
Around view monitor control unit B83
Condition
Voltage
(Approx.)
(+)
(-)
Terminal
Terminal
14
13
CAMERA switch is ON or shift position is R.
6.2 V
Is the inspection result normal?
YES
Replace LH side camera. Refer to Removal and Installation .
NO
Replace around view monitor control unit. Refer to Removal and Installation .
- CHECK RH SIDE CAMERA POWER SUPPLY AND POWER SUPPLY GROUND CIRCUIT CONTINUITY
- Turn ignition switch OFF.
- Disconnect around view monitor control unit connector B83 and RH side camera connector D107.
- Check continuity between around view monitor control unit connector B83 and RH side camera connector D107.
Around view monitor control unit
RH side camera
Continuity
Connector
Terminal
Connector
Terminal
B83
10
D107
7
Yes
9
19
- Check continuity between around view monitor control unit connector B83 and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
B83
10
-
No
Is the inspection result normal?
YES
GO TO 9 .
NO
Repair or replace harness or connectors.
- CHECK AROUND VIEW MONITOR CONTROL UNIT VOLTAGE
- Connect around view monitor control unit connector B83 and RH side camera connector D107.
- Turn ignition switch ON.
- Check voltage between around view monitor control unit connector B83 terminals.
Around view monitor control unit B83
Condition
Voltage
(Approx.)
(+)
(-)
Terminal
Terminal
10
9
CAMERA switch is ON or shift position is R.
6.2 V
Is the inspection result normal?
YES
Replace LH side camera. Refer to Removal and Installation .
NO
Replace around view monitor control unit. Refer to Removal and Installation .