Diagnosis Procedure
- CHECK OPTICAL SENSOR POWER SUPPLY INPUT
- Turn ignition switch ON.
- Turn lighting switch to AUTO.
- Check voltage between optical sensor harness connector M52 and ground.
(+)
(-)
Voltage
(Approx.)
Optical sensor
Connector
Terminal
M52
1
Ground
5 V
Is the inspection result normal?
YES
GO TO 2 .
NO
GO TO 4 .
- CHECK OPTICAL SENSOR GROUND INPUT
Check voltage between optical sensor harness connector M52 and ground.
(+)
(-)
Voltage
(Approx.)
Optical sensor
Connector
Terminal
M52
3
Ground
0 V
Is the inspection result normal?
YES
GO TO 3 .
NO
GO TO 6 .
- CHECK OPTICAL SENSOR SIGNAL OUTPUT
While illuminating the optical sensor, check voltage between optical sensor harness connector M52 and ground.
(+)
(-)
Condition
Voltage
(Approx.)
Optical sensor
Connector
Terminal
M52
2
Ground
Optical sensor
When illuminating
3.1 V or more *
When shutting off light
0.6 V or less
*: Illuminate the optical sensor. The value may be less than the standard if brightness is weak.
Is the inspection result normal?
YES
GO TO 7 .
NO
Replace the optical sensor. Refer to Removal and Installation .
- CHECK OPTICAL SENSOR (OPEN) CIRCUIT
- Turn ignition switch OFF.
- Disconnect optical sensor connector and BCM connector M18.
- Check continuity between optical sensor harness connector M52 and BCM harness connector M18.
Optical sensor
BCM
Continuity
Connector
Terminal
Connector
Terminal
M52
1
M18
3
Yes
Is the inspection result normal?
YES
GO TO 5 .
NO
Repair or replace the harness or connector.
- CHECK OPTICAL SENSOR (SHORT) CIRCUIT
Check continuity between optical sensor harness connector M52 and ground.
Optical sensor
Ground
Continuity
Connector
Terminal
M52
1
No
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace the harness or connector.
- CHECK OPTICAL SENSOR GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect optical sensor connector M52 and BCM connector M18.
- Check continuity between optical sensor harness connector M52 and BCM harness connector M18.
Optical sensor
BCM
Continuity
Connector
Terminal
Connector
Terminal
M52
3
M18
17
Yes
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace the harness connector.
- CHECK OPTICAL SENSOR SIGNAL CIRCUIT (OPEN)
- Turn ignition switch OFF.
- Disconnect optical sensor connector M52 and BCM connector M18.
- Check continuity between optical sensor harness connector M52 and BCM harness connector M18.
Optical sensor
BCM
Continuity
Connector
Terminal
Connector
Terminal
M52
2
M18
4
Yes
Is the inspection result normal?
YES
GO TO 8 .
NO
Repair or replace the harness or connector.
- CHECK OPTICAL SENSOR CIRCUIT (SHORT)
Check continuity between optical sensor harness connector M52 and ground.
Optical sensor
Ground
Continuity
Connector
Terminal
M52
2
No
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace the harness or connector.