Diagnosis Procedure
- CHECK HAZARD SWITCH SIGNAL INPUT
- Turn ignition switch OFF.
- Disconnect hazard switch connector M47.
- Check voltage between hazard switch harness connector M47 and ground.
(+)
(-)
Voltage
(Approx.)
Hazard switch
Connector
Terminal
M47
2
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 4 .
NO
GO TO 2 .
- CHECK HAZARD SWITCH SIGNAL CIRCUIT (OPEN)
- Disconnect BCM connector.
- Check continuity between hazard switch harness connector M47 and BCM harness connector M18.
Hazard switch
BCM
Continuity
Connector
Terminal
Connector
Terminal
M47
2
M18
36
Yes
Is the inspection result normal?
YES
GO TO 3 .
NO
Repair or replace the harness or connector.
- CHECK HAZARD SWITCH SIGNAL CIRCUIT (SHORT)
Check continuity between hazard switch harness connector M47 and ground.
Hazard switch
Ground
Continuity
Connector
Terminal
M45
2
No
Is the inspection result normal?
YES
Replace BCM. Refer to Removal and Installation .
NO
Repair or replace the harness or connector.
- CHECK HAZARD SWITCH GROUND CIRCUIT
Check continuity between hazard switch harness connector M47 and ground.
Hazard switch
Ground
Continuity
Connector
Terminal
M47
3
Yes
Is the inspection result normal?
YES
Replace hazard switch. Refer to Removal and Installation .
NO
Repair or replace the harness or connector.