Test Reading
Recirculating-to-discharge Air Temperature Table
|
Inside air (Recirculating air) at blower assembly inlet |
Discharge air temperature at center ventilator °C (°F) |
|
|
Relative humidity % |
Air temperature °C (°F) |
|
|
50 - 60 |
25 (77) |
10.0 - 12.3 (50 - 54) |
|
30 (86) |
13.2 - 15.3 (56 - 60) |
|
|
35 (95) |
17.2 - 21.0 (63 - 70) |
|
|
60 - 70 |
25 (77) |
12.3 - 14.9 (54 - 59) |
|
30 (86) |
15.3 - 19.3 (60 - 67) |
|
|
35 (95) |
21.0 - 24.4 (70 - 76) |
|
|
Ambient Air |
High-Pressure (Discharge Side) kPa (kg/cm2, psi) |
Low-Pressure (Suction Side) kPa (kg/cm2, psi) |
|
|
Relative humidity % |
Air temperature °C (°F) |
||
|
50 - 70 |
30 (86) |
1, 220 - 1, 500 (12.44 - 15.30, 176.9 - 217.5) |
240 - 295 (2.45 - 3.01, 34.8 - 42.8) |
|
35 (95) |
1, 360 - 1, 690 (13.87 - 17.24, 197.2 - 245.1) |
275 - 335 (2.81 - 3.42, 39.9 - 48.6) |
|
|
40 (104) |
1, 500 - 1, 830 (12.44 - 18.67, 176.9 - 265.4) |
310 - 375 (3.16 - 3.83, 45.0 - 54.4) |
|