Diagnosis Procedure
- CHECK FRONT COMBINATION LAMP SHORT CIRCUIT TO GROUND
- Disconnect front combination lamp LH connector, front combination lamp RH connector and IPDM E/R connector.
- Check continuity between IPDM E/R harness connector and ground.
IPDM E/R
Ground
Continuity
Connector
Terminal
No
E43
56
E44
61
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to Removal and Installation .
NO
Repair or replace harness.