DTC Diagnosis Procedure
- CHECK CONNECTOR
Check combination meter, triple meter and terminals (combination meter side, triple meter side, and harness side) for looseness or bent.
Is the inspection result normal?
YES
GO TO 2.
NO
Repair terminal or connector.
- CHECK CONTINUITY COMMUNICATION CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector and triple meter connector.
- Check continuity between combination meter harness connector and triple meter harness connector.
Combination meter
Triple meter
Continuity
Connector
Terminal
Connector
Terminal
M53
9
M242
4
Existed
10
5
- Check continuity between combination meter harness connector and ground.
Combination meter
Ground
Continuity
Connector
Terminal
M53
9
Ground
Not existed
10
Is the inspection result normal?
YES
GO TO 3.
NO
Repair harness or connector.
- CHECK COMBINATION METER OUTPUT VOLTAGE
- Connect combination meter connector.
- Turn ignition switch ON.
- Check voltage between combination meter harness connector and ground.
Terminals
Voltage
(Approx.)
(+)
(-)
Combination meter
Connector
Terminal
Ground
M53
10
Ground
5 V
Is the inspection result normal?
YES
GO TO 4.
NO
Replace combination meter.
- CHECK TRIPLE METER OUTPUT VOLTAGE
- Turn ignition switch OFF.
- Disconnect combination meter connector.
- Connect triple meter connector.
- Turn ignition switch ON.
- Check voltage between triple meter harness connector and ground.
Terminals
Voltage
(Approx.)
(+)
(-)
Triple meter
Connector
Terminal
Ground
M242
4
Ground
5 V
Is the inspection result normal?
YES
INSPECTION END
NO
Replace triple meter.