Diagnosis Procedure
- CHECK AMBIENT SENSOR SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector and ambient sensor connector.
- Check continuity between combination meter harness connector and ambient sensor harness connector.
Combination meter
Ambient sensor
Continuity
Connector
Terminal
Connector
Terminal
M24
19
E67
1
Yes
- Check continuity between combination meter harness connector and ground.
Combination meter
Ground
Continuity
Connector
Terminal
M24
19
No
Is the inspection result normal?
YES
GO TO 2 .
NO
Repair or replace harness or connector.
- CHECK AMBIENT SENSOR SIGNAL GROUND CIRCUIT
Check continuity between combination meter harness connector and ambient sensor harness connector.
Combination meter
Ambient sensor
Continuity
Connector
Terminal
Connector
Terminal
M24
20
E67
2
Yes
Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace harness or connector.