Component Inspection
- CHECK AMBIENT SENSOR
- Turn ignition switch OFF.
- Disconnect ambient sensor connector.
- Check resistance between ambient sensor terminals.
Terminal
Condition
Resistance: k?
Temperature: °C (°F)
1
2
-15 (5)
12.73
-10 (14)
9.92
-5 (23)
7.80
0 (32)
6.19
5 (41)
4.95
10 (50)
3.99
15 (59)
3.24
20 (68)
2.65
25 (77)
2.19
30 (86)
1.81
35 (95)
1.51
40 (104)
1.27
45 (113)
1.07
Is the inspection result normal?
YES
Inspection End.
NO
Replace ambient sensor. Refer to Removal and Installation .