Component Inspection
WARNING: This page is about a different variant/trim than selected.
- COMBINATION SWITCH (SPIRAL CABLE)
Check continuity between combination switch (spiral cable) connector terminals.
Combination switch (spiral cable)
Continuity
Terminal
4- 32
Existed
5- 33
6 - 31
Is the inspection result normal?
YES
INSPECTION END
NO
Replace combination switch (spiral cable). Refer to SPIRAL CABLE : Removal & Installation .