LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2019 >> Altima Edition ONE >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 10 (Engine Control System (DTC/Circuit Diagnosis) (Pr25DD) (3 Of 4)) >> DTC/Circuit Diagnosis >> P2008 Intake Manifold Runner Control Valve >> DTC Diagnosis Procedure >> PR25DD engine

PR25DD engine

WARNING: This page is about a different variant/trim than selected.
  1. CHECK INTAKE MANIFOLD RUNNER CONTROL VALVE MOTOR POWER SUPPLY CIRCUIT-I 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connectors.
    3. Turn ignition switch ON.
    4. Check the voltage between ECM harness connector terminals.

      ECM

      Voltage

      (Approx.)

      +

      -

      Connector

      Terminal

      Connector

      Terminal

      F90

      96

      E31

      162

      Battery voltage

    Is inspection result normal?

    YES

    GO TO 3.

    NO

    GO TO 2.

  2. CHECK INTAKE MANIFOLD RUNNER CONTROL VALVE MOTOR POWER SUPPLY CIRCUIT-II 

    Check the voltage between ECM harness connector and ground.

    +

    -

    Voltage

    (Approx.)

    ECM

    Connector

    Terminal

    F90

    96

    Ground

    Battery voltage

    Is inspection result normal?

    YES

    GO TO 4.

    NO

    Perform the trouble diagnosis for power supply circuit.

  3. CHECK INTAKE MANIFOLD RUNNER CONTROL VALVE INPUT SIGNAL CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect intake manifold runner control valve motor harness connector.
    3. Check the continuity between ECM harness connector and intake manifold runner control valve motor harness connector.

      +

      -

      Continuity

      Intake manifold runner control valve motor

      ECM

      Connector

      Terminal

      Connector

      Terminal

      F41

      1

      F90

      91

      Not existed

      92

      Existed

      2

      91

      Existed

      92

      Not existed

    4. Also check harness for short to ground.

    Is inspection result normal?

    YES

    GO TO 5.

    NO

    Repair or replace error-detected parts.

  4. CHECK ECM GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Check the continuity between ECM harness connector and the ground.

      ECM

      Ground

      Continuity

      Connector

      Terminal

      F91

      5

      Ground

      Existed

      65

      F90

      69

      70

      E31

      157

      159

      162

    Is inspection result normal?

    YES

    Check intermittent incident. Refer to Inspection .

    NO

    Repair or replace error-detected parts.

  5. CHECK INTAKE MANIFOLD RUNNER CONTROL VALVE 

    Check Intake manifold runner control valve. Refer to DTC Description .

    Is inspection result normal?

    YES

    Check intermittent incident. Refer to Inspection .

    NO

    Replace error-detected parts.