Home >> Nissan-Datsun >> 2019 >> Altima Edition ONE >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 10 (Engine Control System (DTC/Circuit Diagnosis) (Pr25DD) (3 Of 4)) >> DTC/Circuit Diagnosis >> P2004 Intake Manifold Runner Control Valve >> DTC Diagnosis Procedure >> PR25DD engine

PR25DD engine

WARNING: This page is about a different variant/trim than selected.
  1. CHECK INTAKE MANIFOLD RUNNER CONTROL VALVE MOTOR POWER SUPPLY 
    1. Turn ignition switch ON.
    2. Check the voltage between ECM harness connector.

      ECM

      Voltage

      +

      -

      Connector

      Terminal

      Connector

      Terminal

      F90

      96

      E31

      162

      Battery voltage

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    GO TO 2.

  2. CHECK INTAKE MANIFOLD RUNNER CONTROL VALVE MOTOR POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Disconnect IPDM E/R harness connector.
    4. Check the continuity between ECM harness connector and IPDM E/R harness connector.

      +

      -

      Continuity

      ECM

      IPDM E/R

      Connector

      Terminal

      Connector

      Terminal

      F90

      96

      F10

      78

      Existed

    5. Also check harness for short to ground.

    Is the inspection result normal?

    YES

    Perform the trouble diagnosis for power supply circuit.

    NO

    Repair or replace error-detected parts.

  3. CHECK INTAKE MANIFOLD RUNNER CONTROL VALVE MOTOR OUTPUT SIGNAL CIRCUIT 
    1. Disconnect intake manifold runner control valve motor harness connector.
    2. Check the continuity between intake manifold runner control valve motor harness connector and ECM harness connector.

      +

      -

      Continuity

      Intake manifold runner control valve motor

      ECM

      Connector

      Terminal

      Connector

      Terminal

      F41

      1

      F90

      91

      Not existed

      92

      Existed

      2

      91

      Existed

      92

      Not existed

    3. Also check harness for short to ground and to power.

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Repair or replace error-detected parts.

  4. CHECK INTAKE MANIFOLD RUNNER CONTROL VALVE MOTOR 

    Check the intake manifold runner control valve motor. Refer to Component Inspection .

    Is the inspection result normal?

    YES

    Check intermittent incident. Refer to Inspection .

    NO

    Replace intake manifold assembly. Refer to Removal & Installation .