PR25DD engine
- CHECK DTC PRIORITY
If DTC P119C is displayed with DTC P0190, first perform the trouble diagnosis for DTC P0190.
Is applicable DTC detected?
YES
Perform diagnosis of applicable. DTC Description
NO
GO TO 2.
- CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-1
- Turn ignition switch OFF.
- Disconnect FRP sensor connector.
- Turn ignition switch ON.
- Check the voltage between FRP sensor harness connector terminals.
FRP sensor
Voltage
(Approx.)
Connector
+
-
terminal
F116
3
1
5 V
Inspection result normal?
YES
GO TO 8.
NO
GO TO 3.
- CHECK FRP SENSOR POWER SUPPLY-2
Check the voltage between FRP sensor harness connector and the ground.
+
-
Voltage
(Approx.)
FRP sensor
Connector
Terminal
F116
3
Ground
5 V
Is inspection result normal?
YES
GO TO 6.
NO
GO TO 4.
- CHECK FRP SENSOR POWER SUPPLY CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F116
3
F91
43
Existed
- Also check harness for short to power.
Is inspection result normal?
YES
GO TO 5.
NO
Repair or replace error-detected parts.
- CHECK SENSOR POWER SUPPLY 2 CIRCUIT
Refer to Diagnosis Procedure .
Is inspection result normal?
YES
Perform the trouble diagnosis for ECM power supply circuit. Refer to Diagnosis Procedure .
NO
Repair or replace error-detected parts.
- CHECK FRP SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F116
1
F91
45
Existed
- Also check harness for short to power.
Is inspection result normal?
YES
GO TO 7.
NO
Repair or replace error-detected parts.
- CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT
- Check the continuity between ECM harness connector and ground.
ECM
Ground
Continuity
Connector
Terminal
F91
5
Ground
Existed
65
F90
69
70
E31
157
159
162
- Also check harness for short to power.
Is the inspection result normal?
YES
INSPECTION END
NO
Repair or replace error-detected parts.
- Check the continuity between ECM harness connector and ground.
- CHECK FRP SENSOR SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor
ECM
Continuity
Connector
Terminal
Connector
Terminal
F116
2
F91
44
Existed
- Also check harness for short to ground and to power.
Is inspection result normal?
YES
GO TO 9.
NO
Repair or replace error-detected parts.
- CHECK FRP SENSOR
Check the FRP sensor. Refer to Component Inspection .
Is inspection result normal?
YES
INSPECTION END
NO
Repair or replace error-detected parts.