CVT: Re0F10D
If multiple malfunction codes are detected at the same time, check each code according to the DTC check priority list below.
|
Priority |
DTC |
Items (CONSULT screen terms) |
Reference |
|
1 |
P0863 |
CONTROL UNIT (CAN) |
|
|
U0073 |
COMM BUS A OFF |
||
|
U0100 |
LOST COMM (ECM A) |
||
|
U0102 |
LOST COMM (TRANSFER) |
||
|
U0140 |
LOST COMM (BCM) |
||
|
U0141 |
LOST COMM (BCM A) |
||
|
U0155 |
LOST COMM (IPC) |
||
|
U0164 |
LOST COMM (HVAC) |
||
|
U0300 |
CAN COMM DATA |
||
|
U1000 |
CAN COMM CIRC |
||
|
U1117 |
LOST COMM (ABS) |
||
|
2 |
P0740 |
TORQUE CONVERTER |
|
|
P0742 |
TORQUE CONVERTER |
||
|
P0743 |
TORQUE CONVERTER |
||
|
P0778 |
PC SOLENOID B |
||
|
P0779 |
PC SOLENOID B |
||
|
P0962 |
PC SOLENOID A |
||
|
P0963 |
PC SOLENOID A |
||
|
P0966 |
PC SOLENOID B |
||
|
P0967 |
PC SOLENOID B |
||
|
P2758 |
TCC PRESSURE CONT SOLENOID |
||
|
P2814 |
SELECT SOLENOID |
||
|
P2815 |
SELECT SOLENOID |
||
|
3 |
P0605 |
CONTROL MODULE ROM |
|
|
P062F |
EEPROM |
||
|
P0705 |
T/M RANGE SENSOR A |
||
|
P0706 |
T/M RANGE SENSOR A |
||
|
P0711 |
FLUID TEMP SENSOR A |
||
|
P0712 |
FLUID TEMP SENSOR A |
||
|
P0713 |
FLUID TEMP SENSOR A |
||
|
P0715 |
INPUT SPEED SENSOR A |
||
|
P0716 |
INPUT SPEED SENSOR A |
||
|
P0717 |
INPUT SPEED SENSOR A |
||
|
P0718 |
INPUT SPEED SENSOR A |
||
|
P0791 |
INTERMEDIATE SPEED SENSOR A |
||
|
P0792 |
INTERMEDIATE SPEED SENSOR A |
||
|
P0793 |
INTERMEDIATE SPEED SENSOR A |
||
|
P0794 |
INTERMEDIATE SPEED SENSOR A |
||
|
P0841 |
FLUID PRESS SEN/SW A |
||
|
P0847 |
FLUID PRESS SEN/SW B |
||
|
P0848 |
FLUID PRESS SEN/SW B |
||
|
P084C |
FLUID PRESS SEN/SW H |
||
|
P084D |
FLUID PRESS SEN/SW H |
||
|
P0890 |
TCM |
||
|
P2765 |
INPUT SPEED SENSOR B |
||
|
P2766 |
INPUT SPEED SENSOR B |
||
|
P2767 |
INPUT SPEED SENSOR B |
||
|
P2768 |
INPUT SPEED SENSOR B |
||
|
4 |
P0741 |
TORQUE CONVERTER |
|
|
P0746 |
PC SOLENOID A |
||
|
P0776 |
PC SOLENOID B |
||
|
P0965 |
PC SOLENOID B |
||
|
P17F0 |
CV JUDDER (T/M INSPECTION) |
||
|
P17F1 |
CV JUDDER (C/V INSPECTION) |
||
|
P17F2 |
CV JUDDER (T/C INSPECTION) |
||
|
P187E |
T/M SYSTEM MULFUNCTION |
||
|
P2813 |
SELECT SOLENOID |