Diagnosis Procedure
- CHECK TRIP RESET SWITCH SIGNAL
- Ignition switch ON.
- Check voltage between the following terminals of the trip reset switch harness connector.
Trip reset switch
Condition
Voltage
(Approx.)
Connector
Terminals
(+)
(-)
M140
6
8
When trip reset switch is pressed
0 V
Other than the above
5 V
Is the inspection result normal?
YES
Inspection End.
NO
GO TO 2.
- CHECK TRIP RESET SWITCH HARNESS
- Ignition switch OFF.
- Disconnect combination meter harness connector and trip reset switch harness connector.
- Check continuity between combination meter harness connector and trip reset switch harness connector.
Combination meter
Trip reset switch
Continuity
Connector
Terminal
Connector
Terminal
M24
14
M140
8
Yes
34
6
- Check continuity between combination meter harness connector and ground.
Combination meter
Ground
Continuity
Connector
Terminal
M24
14
No
34
Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace harness or connector.