Data Monitor
|
Item [Indication/Unit] |
Description |
|
|
ACTUATOR VOLT (RH) |
[V] |
Displays the voltage value applied to the parking brake actuator (RH side). |
|
ACTUATOR VOLT (LH) |
[V] |
Displays the voltage value applied to the parking brake actuator (LH side). |
|
ACTUATOR CURRENT (RH) |
[A] |
Displays the current value applied to the parking brake actuator (RH side). |
|
ACTUATOR CURRENT (LH) |
[A] |
Displays the current value applied to the parking brake actuator (LH side). |
|
POWER SUPPLY VOLTAGE |
[V] |
Displays the power supply voltage. |
|
ACTUATOR POWER SUP (RH) |
[High or not high] |
Displays the voltage output to the actuator (RH). |
|
ACTUATOR POWER SUP (LH)) |
[High or not high] |
Displays the voltage output to the actuator (LH). |
|
PB SW |
[PULL/N/PUSH/MALF] |
Displays the electric parking brake switch status. |
|
BRAKE STATUS (LH) |
[ACT 1/ACT 2/ACT 3/RLS 1/RLS 2/UNKNO/INIT/RLS 3/RLS 4] |
Displays the piston status of the rear brake caliper assembly (LH side) [parking brake actuator (LH side) driving status]. |
|
BRAKE STATUS (RH) |
[ACT 1/ACT 2/ACT 3/RLS 1/RLS 2/UNKNO/INIT/RLS 3/RLS 4] |
Displays the piston status of the rear brake caliper assembly (RH side) [parking brake actuator (LH side) driving status]. |
|
PB SW OPERATION COUNT 1 |
Displays the number of operations of the electric parking brake system switch (Count 1). |
|
|
PB SW OPERATION COUNT 2 |
Displays the number of operations of the electric parking brake system switch (Count 2). |
|
|
PB ACT COUNTER (LH) |
Displays the number of operations of the electric parking brake system (LH side). |
|
|
PB ACT COUNTER (RH) |
Displays the number of operations of the electric parking brake system (RH side). |
|
|
PB SW INDICATOR * |
[Off/On/BLINK] |
Displays the status of electric parking brake switch indicator. |
*: Refer to System Description for ON/OFF/BRINK conditions of each warning lamp and each indicator lamp, buzzer and information display in the combination meter.