Diagnosis Procedure
- CHECK ELECTRIC PARKING BRAKE CONTROL MODULE IGNITION POWER SUPPLY
- Ignition switch OFF.
- Disconnect the electric parking brake control module harness connector.
- Check the voltage between electric parking brake control module harness connector and ground.
Electric parking brake control module
--
Voltage
(Approx.)
Connector
Terminal
M167
6
Ground
Battery voltage
- Ignition switch ON
- Check the voltage between electric parking brake control module harness connector and ground.
Electric parking brake control module
--
Voltage
(Approx.)
Connector
Terminal
M167
6
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK ELECTRIC PARKING BRAKE CONTROL MODULE IGNITION POWER SUPPLY CIRCUIT
- Iignition switch OFF.
- Check 5A fuse (#37).
- Check the continuity between electric parking brake control module harness connector and fuse block (J/B) harness connector.
Electric parking brake control module
Fuse block (J/B)
Continuity
Connector
Terminal
Connector
Terminal
M167
6
M5
6P
Yes
Is the inspection result normal?
YES
Perform trouble diagnosis for ignition power supply.
NO
Repair or replace error-detected parts.
- CHECK MOTOR POWER SUPPLY
- Ignition switch OFF.
- Check the voltage between electric parking brake control module harness connector and ground.
Electric parking brake control module
--
Voltage
(Approx.)
Connector
Terminal
M167
8
Ground
Battery voltage
M168
27
32
- Ignition switch ON
- Check the voltage between electric parking brake control module harness connector and ground.
Electric parking brake control module
--
Voltage
(Approx.)
Connector
Terminal
M167
8
Ground
Battery voltage
M168
27
32
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 4.
- CHECK MOTOR POWER SUPPLY CIRCUIT
- Ignition switch OFF.
- Check the 10A fuse (#6).
- Check the 30A fuse (#65) and 30A fuse (#72).
- Check the continuity and short circuit between electric parking brake control module harness connector terminal and 10A fuse (#6).
- Check the continuity and short circuit between electric parking brake control module harness connector terminal and 30A fuse (#65).
- Check the continuity and short circuit between electric parking brake control module harness connector terminal and 30A fuse (#72).
Is the inspection result normal?
YES
Perform trouble diagnosis for battery power supply.
NO
Repair or replace error-detected parts.
- CHECK ELECTRIC PARKING BRAKE CONTROL MODULE GROUND CIRCUIT
- I ignition switch OFF.
- Check for continuity between electric parking brake control module harness connector and the ground.
Electric parking brake control module
--
Continuity
Connector
Terminal
M168
29
Ground
Yes
30
Is the inspection result normal?
YES
GO TO 6.
NO
Repair or replace error-detected parts.
- CHECK TERMINAL
Check electric parking brake control module pin terminals for damage or loose connection with harness connector.
Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace error-detected parts.