Diagnosis Procedure
Detects door open/close condition.
- CHECK DOOR SWITCH INPUT SIGNAL
- Ignition switch OFF.
- Check signal between BCM connector and ground with oscilloscope.
(+)
(-)
Door condition
Voltage
(Approx.)
BCM
Connector
Terminal
B71
57
Ground
Front door switch LH
OPEN
0
CLOSE
53
Front door switch RH
OPEN
0
CLOSE
50
Rear door switch RH
OPEN
0
CLOSE
52
Rear door switch LH
OPEN
0
CLOSE
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 2.
- CHECK DOOR SWITCH CIRCUIT
- Disconnect BCM connector and door switch connector.
- Check continuity between BCM connector and door switch connector.
BCM
Door switch
Continuity
Connector
Terminal
Connector
Terminal
B71
57
Front door switch LH
3
Yes
53
Front door switch RH
50
Rear door switch RH
52
Rear door switch LH
- Check continuity between BCM connector and ground.
BCM
Ground
Continuity
Connector
Terminal
B71
57
No
53
50
52
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace harness between BCM and door switch.
- CHECK DOOR SWITCH
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 4.
NO
Replace malfunctioning door switch. Refer to DOOR SWITCH : Removal & Installation .
- CHECK INTERMITTENT INCIDENT
Refer to Inspection .
Inspection End.