Component Inspection
- CHECK AMBIENT SENSOR
- Turn Ignition Switch OFF.
- Disconnect Ambient Sensor Connector.
- Check Resistance Between Ambient Sensor Terminals.
Terminal
Condition
Resistance: kΩ
Temperature: °C (°F)
1
2
- 15 (5)
12.73
- 10 (14)
9.92
- 5 (23)
7.80
0 (32)
6.19
5 (41)
4.95
10 (50)
3.99
15 (59)
3.24
20 (68)
2.65
25 (77)
2.19
30 (86)
1.81
35 (95)
1.51
40 (104)
1.27
45 (113)
1.07
Is The Inspection Result Normal?
YES
Inspection End.
NO
Replace Ambient Sensor. Refer To REMOVAL AND INSTALLATION .