Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK METER CONTROL SWITCH SIGNAL
- Turn ignition switch ON.
- Check voltage between the following terminals of the meter control switch harness connector M3.
Meter control switch Condition Voltage
(Approx.)Connector Terminals (+) (-) M3 7 4 When illumination control switch (-) is pressed 0 V Other than the above 5 V 5 When trip reset switch is pressed 0 V Other than the above 5 V 6 When illumination control switch (+) is pressed 0 V Other than the above 5 V
Is the inspection result normal?
YES
Inspection End.
NO
GO TO STEP 2.
- CHECK METER CONTROL SWITCH HARNESS
- Turn ignition switch OFF.
- Disconnect combination meter harness connector M77 and meter control switch harness connector M3.
- Check continuity between combination meter harness connector M77 and meter control switch harness connector M3.
Combination meter Meter control switch Continuity Connector Terminal Connector Terminal M77 18 M3 5 Yes 37 7 36 6 17 4 - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M77 18 No 37 36 17
Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace harness or connectors.