Component Inspection
- CHECK METER CONTROL SWITCH
- Turn ignition switch OFF.
- Disconnect meter control switch connector.
- Check meter control switch.
Meter control switch Condition Continuity Terminals 7 4 When illumination control switch (-) is pressed Yes Other than the above No 5 When trip reset switch is pressed Yes Other than the above No 6 When illumination control switch (+) is pressed Yes Other than the above No
Is the inspection result normal?
YES
Inspection End.
NO
Replace meter control switch. Refer to REMOVAL AND INSTALLATION .