Component Inspection
- CHECK AMBIENT SENSOR
- Turn ignition switch OFF.
- Disconnect ambient sensor connector.
- Check resistance between ambient sensor terminals.
Ambient sensor Resistance: kΩ Terminal Condition Temperature: °C (°F) 1 2 - 15 (5) 12.73 - 10 (14) 9.92 - 5 (23) 7.80 0 (32) 6.19 5 (41) 4.95 10 (50) 3.99 15 (59) 3.24 20 (68) 2.65 25 (77) 2.19 30 (86) 1.81 35 (95) 1.51 40 (104) 1.27 45 (113) 1.07
Is the inspection result normal?
YES
Inspection End.
NO
Replace ambient sensor. Refer to REMOVAL AND INSTALLATION .