Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK FUSES
Check that the following fuses are not blown.
Unit Power source Fuse No. Combination meter Battery 13 Ignition switch ON or START 31 Is the fuse blown?
YES
Replace the blown fuse after repairing the affected circuit.
NO
GO TO STEP 2 .
- CHECK POWER SUPPLY CIRCUIT
- Disconnect combination meter connector.
- Check voltage between combination meter harness connector M77 terminals 45, 46 and ground.
Combination meter Ground Ignition switch position Connector Terminal OFF ON START M77 45 (-) Battery voltage Battery voltage Battery voltage 46 0V Battery voltage Battery voltage Is the inspection result normal?
YES
GO TO STEP 3.
NO
Repair or replace harness or connector.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M76 1 (-) Yes M77 52 Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace harness or connector.