Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK INTELLIGENT KEY WARNING BUZZER CIRCUIT
- Disconnect BCM connector.
- Check continuity between BCM harness connector and Intelligent Key warning buzzer harness connector.
BCM Intelligent Key warning buzzer Continuity Connector Terminal Connector Terminal E29 132 E24 1 Yes - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal E29 132 No
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair or replace harness.
- CHECK INTELLIGENT KEY WARNING BUZZER
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Replace Intelligent Key warning buzzer. Refer to REMOVAL AND INSTALLATION .