Diagnosis Procedure
- CHECK FRONT COMBINATION LAMP LH SHORT CIRCUIT TO GROUND
- Disconnect front combination lamp LH connector and IPDM E/R connector.
- Check continuity between IPDM E/R harness connector and ground.
IPDM E/R Ground Continuity Connector Terminal E217 53 No Is the inspection result normal?
YES
GO TO 2.
NO
Repair or replace harness.
- CHECK FRONT COMBINATION LAMP LH SHORT CIRCUIT TO GROUND
- Reconnect IPDM E/R connector.
- Check continuity between front combination lamp LH harness connector and ground.
Front combination lamp LH Ground Ground Connector Terminal E239 7 No Is the inspection result normal?
YES
Replace front combination lamp LH. Refer to REMOVAL AND INSTALLATION .
NO
Replace IPDM E/R. Refer to REMOVAL AND INSTALLATION .