Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK OUTPUT 1 - 5 SYSTEM CIRCUIT FOR OPEN
- Turn ignition switch OFF.
- Disconnect BCM connector M19 and combination switch connector.
- Check continuity between BCM connector M19 and combination switch connector M28.
Combination switch signal BCM Combination switch Continuity Connector Terminal Connector Terminal OUTPUT 1 M19 85 M28 2 Yes OUTPUT 2 84 10 OUTPUT 3 86 15 OUTPUT 4 87 4 OUTPUT 5 34 7
Is the inspection result normal?
YES
GO TO STEP 2.
NO
Repair or replace harness or connectors.
- CHECK OUTPUT 1 - 5 SYSTEM CIRCUIT FOR SHORT
Check continuity between BCM connector M19 and ground.
Combination switch signal BCM Ground Continuity Connector Terminal OUTPUT 1 M19 85 No OUTPUT 2 84 OUTPUT 3 86 OUTPUT 4 87 OUTPUT 5 34 Is the inspection result normal?
YES
GO TO STEP 3.
NO
Repair or replace harness or connectors.
- CHECK BCM INPUT VOLTAGE
- Connect BCM connector M19 and combination switch connector.
- Turn ignition switch ON.
- Check voltage between BCM connector M19 and ground.
Combination switch signal BCM Ground Voltage Connector Terminal OUTPUT 1 M19 85 - Refer to REFERENCE VALUE . OUTPUT 2 84 OUTPUT 3 86 OUTPUT 4 87 OUTPUT 5 34
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Replace the combination switch. Refer to REMOVAL AND INSTALLATION .