Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK INPUT 1 - 5 SYSTEM CIRCUIT FOR OPEN
- Turn ignition switch OFF.
- Disconnect BCM connector M18 and combination switch connector.
- Check continuity between BCM connector M18 and combination switch connector M28.
Combination switch signal BCM Combination switch Continuity Connector Terminal Connector Terminal INPUT 1 M18 38 M28 8 Yes INPUT 2 39 6 INPUT 3 36 5 INPUT 4 37 3 INPUT 5 33 1
Is the inspection result normal?
YES
GO TO STEP 2.
NO
Repair or replace harness or connectors.
- CHECK INPUT 1 - 5 SYSTEM CIRCUIT FOR SHORT
Check continuity between BCM connector M18 and ground.
Combination switch signal BCM Ground Continuity Connector Terminal INPUT 1 M18 38 No INPUT 2 39 INPUT 3 36 INPUT 4 37 INPUT 5 33 Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace harness or connectors.
- CHECK BCM OUTPUT VOLTAGE
- Connect BCM connector M18 and combination switch connector.
- Turn ignition switch ON.
- Check voltage between BCM connector M18 and ground.
Combination switch signal BCM Ground Voltage Connector Terminal INPUT 1 M18 38 - Refer to REFERENCE VALUE . INPUT 2 39 INPUT 3 36 INPUT 4 37 INPUT 5 33
Is the inspection result normal?
YES
Replace the combination switch. Refer to REMOVAL AND INSTALLATION .
NO
Replace BCM. Refer to REMOVAL AND INSTALLATION .