Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK FUSES
Check that the following fuses are not blown.
Unit Power source Fuse No. Combination meter Battery 8 Ignition switch ON or ACC 18 Ignition switch ON or START 3 Is the fuse blown?
YES
Replace the blown fuse after repairing the affected circuit.
NO
GO TO STEP 2.
- POWER SUPPLY CIRCUIT CHECK
Check voltage between combination meter harness connector M24 terminals 15, 27, 28 and ground.
Terminals Ignition switch position (+) (-) OFF ACC ON START Connector Terminal M24 27 Ground Battery voltage Battery voltage Battery voltage Battery voltage 15 0V Battery voltage Battery voltage 0V 28 0V 0V Battery voltage Battery voltage Is the inspection result normal?
YES
GO TO STEP 3.
NO
Repair or replace harness or connector.
- CHECK GROUND CIRCUIT
Check continuity between combination meter harness connector M24 terminals 21, 22, 23 and ground.
Combination meter Ground Continuity Connector Terminal M24 21 Yes 22 23 Is the inspection result normal?
YES
Inspection End.
NO
Repair or replace harness or connector.