Diagnosis Procedure
- CHECK WASHER FLUID LEVEL SWITCH SIGNAL CIRCUIT
Check the washer fluid level switch signal circuit. Refer to DIAGNOSIS PROCEDURE .
Is the inspection result normal?
YES
GO TO STEP 2.
NO
Repair or replace harness or connector.
- CHECK WASHER FLUID LEVEL SWITCH
Check for the washer fluid level switch. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
Replace combination meter. Refer to REMOVAL AND INSTALLATION
NO
Replace washer fluid level switch. Refer to REMOVAL AND INSTALLATION .