Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CHECK COMBINATION METER INPUT SIGNAL
- Turn ignition switch ON.
- Check voltage between the following terminals of the illumination control switch.
Illumination control switch Ground Condition Voltage
(Approx.)Connector Terminals M66 1 When illumination control switch (+) is pressed 0 V Other than the above 5 V 2 When illumination control switch (-) is pressed 0 V Other than the above 5 V
Is the inspection result normal?
YES
Inspection End.
NO
GO TO STEP 2.
- CHECK ILLUMINATION CONTROL SWITCH SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector M24 and illumination control switch connector M66.
- Check continuity between combination meter harness connector and illumination control switch harness connector.
Combination meter Illumination control switch Continuity Connector Terminal Connector Terminal M24 33 M66 1 Yes 34 2 - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M24 33 No 34
Is the inspection result normal?
YES
Check illumination control switch. Refer to COMPONENT INSPECTION .
NO
Repair or replace harness or connector.