Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CHECK AMBIENT SENSOR SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector and ambient sensor connector.
- Check continuity between combination meter harness connector and ambient sensor harness connector.
Combination meter Ambient sensor Continuity Connector Terminal Connector Terminal M24 19 E67 1 Yes - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M24 19 No Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace harness or connector.
- CHECK AMBIENT SENSOR SIGNAL GROUND CIRCUIT
Check continuity between combination meter harness connector and ambient sensor harness connector.
Combination meter Ambient sensor Continuity Connector Terminal Connector Terminal M24 20 E67 2 Yes Is the inspection result normal?
YES: Inspection End.
NO: Repair or replace harness or connector.