COMBINATION METER: Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CHECK FUSES
Check that the following fuses are not blown.
Unit Power source Fuse No. Combination meter Battery 13 Ignition switch ON or START 31 Is the fuse blown?
YES: Replace the blown fuse after repairing the affected circuit.
NO: GO TO 2.
- POWER SUPPLY CIRCUIT CHECK
- Disconnect combination meter connector.
- Check voltage between combination meter harness connector M77 terminals 45, 46 and ground.
Terminals Ignition switch position (+) (-) OFF ON START Connector Terminal M77 45 Ground Battery voltage Battery voltage Battery voltage 46 0V Battery voltage Battery voltage Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace harness or connector.
- GROUND CIRCUIT CHECK