Component Inspection (Without Automatic Back Door)
- CHECK BACK DOOR SWITCH
- Turn ignition switch OFF.
- Disconnect back door lock assembly connector.
- Check continuity between back door lock assembly terminals.
Back door lock assembly Condition Continuity Terminal 3 4 Door switch Pressed No Released Yes Is the inspection result normal?
YES: Inspection End.
NO: Replace back door lock assembly. Refer to "DOOR LOCK: REMOVAL AND INSTALLATION ".