Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CHECK METER CONTROL SWITCH SIGNAL
- Turn ignition switch ON.
- Check voltage between the following terminals of the meter control switch harness connector M3.
Meter control switch Condition Voltage (Approx.) Connector Terminals (+) (-) M3 7 4 When illumination control switch (-) is pressed 0 V Other than the above 5 V 5 When trip reset switch is pressed 0 V Other than the above 5 V 6 When illumination control switch (+) is pressed 0 V Other than the above 5 V Is the inspection result normal?
YES: Inspection End.
NO: GO TO 2.
- CHECK METER CONTROL SWITCH HARNESS
- Turn ignition switch OFF.
- Disconnect combination meter harness connector M77 and meter control switch harness connector M3.
- Check continuity between combination meter harness connector M77 and meter control switch harness connector M3.
Combination meter Meter control switch Continuity Connector Terminal Connector Terminal M77 18 M3 5 Yes 37 7 36 6 17 4 - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M77 18 No 37 36 17 Is the inspection result normal?
YES: Inspection End.
NO: Repair or replace harness or connectors.